Fluke 116 Digital Multimeter Fluke 116 Digital Multimeter Specifically designed for HVAC professionals, the Fluke 116 digital multimeter has everything you need in an HVAC meter. Temp and microamp. Learn More. P000172 HVAC IAQ 0 VND Quantity: 1 Cái


  •  
  • Fluke 116 Digital Multimeter

  • Post on 22-09-2015 04:30:55 PM - 1311 Views
  • Price: Contact

  • Specifically designed for HVAC professionals, the Fluke 116 digital multimeter has everything you need in an HVAC meter. Temp and microamp. Learn More.


Quantity
  • Everything You Need in an HVAC Meter

    With the ability to take temperature and microamp measurements, the Fluke 116 Digital Multimeter has everything you need to help you quickly troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116 measures resistance, continuity, frequency and capacitance. Fluke 116 multimeters are independently tested for safe use in CAT III 600 V Environments.

    Specifications
    Maximum voltage between any terminal and earth ground 600 V
    Surge protection 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
    Display Digital: 6,000 counts, updates 4 per second
    Bar graph 33 segments, updates 32 per second
    Operating temperature -10°C to + 50°C
    Storage temperature -40°C to + 60°C
    Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
    Battery life 400 hours typical, without backlight
    Accuracy Specifications
    DC millivolts Range/resolution 600.0 mV / 0.1 mV
    Accuracy ±([% of reading] + [counts]): 0.5% + 2
    DC volts Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.00 V / 0.1 V
    Accuracy ±([% of reading] + [counts]): 0.5% + 2
    Auto volts Range/resolution 600.0 V / 0.1 V
    Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
    4.0% + 3 (500 Hz to 1 kHz)
    AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
    60.00 V / 0.01 V
    600.0 V / 0.1 V
    Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
    2.0% + 3 (500 Hz to 1 kHz)
    Continuity Range/resolution 600 Ω / 1 Ω
    Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
    500 μs or longer.
    Ohms Range/resolution 600.0 Ω / 0.1 Ω
    6.000 kΩ / 0.001 kΩ
    60.00 kΩ / 0.01 kΩ
    600.0 kΩ / 0.1 kΩ
    6.000 MΩ / 0.001 MΩ
    Accuracy 0.9% + 1
    Range/Resolution 40.00 MΩ / 0.01 MΩ
    Accuracy 5% + 2
    Diode Test Range/resolution 2.00 V / 0.001 V
    Accuracy 0.9% + 2
    Capacitance Range/resolution 1000 nF / 1 nF
    10.00 μF / 0.01 μF
    100.0 μF / 0.1 μF
    9999 μF / 1 μF
    100 μF to 1000 μF
    Accuracy 1.9% + 2
    Range/resolution > 1000 μF
    Accuracy 5% + 20%
    Lo-Z Capacitance Range 1 nF to 500 μF
    Accuracy 10% + 2 typical
    Temperature²
    (Type-K thermocouple)
    Range/resolution -40°C to 400°C / 0.1°C
    Accuracy 1% + 10²
    Range/resolution -40°F to 752°F / 0.2°F
    Accuracy 1% + 18²
    AC μA true-rms (45 Hz to 500 Hz) Range/resolution 600.0 μA / 0.1 μA
    Accuracy 1.5% + 3
    DC μamps Range/resolution 600.0 μA / 0.1 μA
    Accuracy 1.0% + 2
    Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
    999.99 Hz / 0.1 Hz
    9.999 Hz / 0.001 Hz
    50.00 Hz / 0.01 Hz
    Accuracy 0.1% + 2
    1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
    2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
    3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
    4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
    Mechanical and General Specifications
    Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
    Weight 550 g
    Warranty 3 years
     

 

  Reader Comments

You did not use the site, Click here to remain logged. Timeout: 60 second